Electrical
Specifications - Inverter |
|
|
Output power
(continuous) |
|
3000 watts |
|
|
Surge rating
(5 seconds) |
|
7500 watts (60
A) |
|
|
Output voltage |
|
120 VAC |
|
|
Output
frequency |
|
60 Hz +/-
0.05% (crystal controlled) |
|
|
Output
waveform |
|
Sine wave (<
5% THD) |
|
|
Peak
Efficiency |
|
> 90% |
|
|
Efficiency
(full load) |
|
> 85% |
|
|
No load power
draw (search mode) |
|
< 20 W |
|
|
AC connections |
|
Split phase in
/ dual out, Dual in / dual out |
|
|
AC transfer
capability |
|
2 legs at 50 A
(split phase in),
2 legs at 30 A (dual in) |
|
|
Transfer time |
|
20 ms
(typical) |
|
|
Electrical
Specifications - Charger |
|
|
Output current |
|
180 A DC |
|
|
Battery
voltage (nominal) |
|
12 VDC |
|
|
Battery
voltage range |
|
10.0 - 15.5
VDC |
|
|
Charge control |
|
3 stage with
manual equalize |
|
|
Charge
temperature compensation |
|
Remote battery
sensor (included) |
|
|
Efficiency |
|
85% typical |
|
|
AC input power
factor |
|
0.95 |
|
|
Input current
(for 150 A charging) |
|
22 A RMS
nominal |
|
|
AC input
voltage |
|
120 VAC
nominal |
|
|
AC input
voltage range |
|
90 - 135 VAC |
|
|
Compatible
battery types |
|
Wet/Gel/AGM |
|
|
General
Specifications |
|
|
Operating
temperature range |
|
-4°F - 122°F
(-20°C - 50°C) |
|
|
Storage
temperature range |
|
-40°F - 122°F
(-40°C - 50°C) |
|
|
Dimensions
(HxWxD) |
|
8.17 x 13.25 x
16" (208 x 336 x 406 mm) |
|
|
Weight |
|
75.0 lb (34.0
kg) |
|
|
Warranty |
|
3 years |
|
|
Part number |
|
809-3000
(Split phase in / Dual out) |
|
|
Accessories |
|
System Control
Panel
Automatic
Generator Start
Network
Connector
Network Cable
3’
Network Cable
5’
Network Cable
7’
Network Cable
10’
Network Cable
14’
Network Cable
25’
Network Cable
50’
Network Cable
75’ |
809-0910
809-0915
809-0903
809-0935
809-0936
809-0937
809-0938
809-0939
809-0940
809-0941
809-0942 |
|
|
Regulatory
Approvals |
|
|
CSA/NRTL
certified to CSA 107.1, UL 458 |
|
|
FCC Class
B/Industry Canada Class |