Electrical Specifications |
|
|
|
Voltage Measurement
(standard model auto range) |
|
8.5-50 VDC (0.05 V resolution) |
|
|
Amperage Measurement
(+/- 500 amps) |
|
Low range 0-40 A +/- 0.1 A resolution |
|
|
|
|
High range 40-500 A +/- 1.0 A resolution |
|
|
Amp-hour Measurement |
|
Low range +/- 0-199.9 Ah (0.1 hour
resolution) |
|
|
|
|
High range +/- 200-1, 999 Ah (1 hour resolution) |
|
|
Time Remaining Measurement |
|
Low range 0-199.9 hours (0.1 hour
resolution) |
|
|
|
|
High range 0-255 hours (1 hour
resolution) |
|
|
Power Requirements |
|
9-40 VDC (DC power supply voltage) |
|
|
Power Consumption |
|
28 mA (adjustable back-light adds 1-18
mA) |
|
|
Shunt Type |
|
500 A/50 mV (included) |
|
|
Accuracy |
|
Voltage +/- 0.6% of reading + 1 least
count of resolution |
|
|
|
|
Amperage +/- 0.8% of reading + 1 least
count of resolution |
|
|
|
|
Amp-hours Ah Error - time measurement x
current error |
|
|
Max. Alternator Output |
|
230 A (200R model only) |
|
|
General Specifications |
|
|
Dimensions (H x W x D) |
|
3.72 x 5.75 x 1.25" (95.25 x 146 x 31.75
mm) |
|
|
Weight (not including shunt) |
|
9 oz (255.2 g) |
|
|
Warranty |
|
1 year |
|
|
Part numbers |
|
84-2005-04 (Link 2000R) |