Electrical Specifications |
|
|
|
Voltage Measurement
(standard model auto range) |
|
0-19.90 VDC (0.05 V resolution)
0.0-50.0 VDC (0.1 V resolution) |
|
|
Amperage Measurement
(+/- 500 amps) |
|
Low range 0-40 A +/- 0.1 A resolution |
|
|
|
|
High range 40-500 A +/- 1.0 A resolution |
|
|
Amp-hour Measurement |
|
Low range +/- 0-199.9 Ah (0.1 hour resolution) |
|
|
|
|
High range +/- 200-1, 999 Ah (1 hour resolution) |
|
|
Time Remaining Measurement |
|
Low range 0-199.9 hours (0.1 hour resolution) |
|
|
|
|
High range 0-255 hours (1 hour resolution) |
|
|
Power Requirements |
|
8-40 VDC (DC power supply voltage) |
|
|
Power Consumption |
|
50-170 mA (display auto dims with ambient light) |
|
|
|
|
25 mA (bar graph display @ 12 V) |
|
|
Shunt Type |
|
500 A/50 mV (included) |
|
|
Accuracy |
|
Voltage +/- 0.6% of reading + 1 least count of
resolution |
|
|
|
|
Amperage +/- 0.8% of reading + 1 least count of
resolution |
|
|
|
|
Amp-hours Ah Error - time measurement x current
error |
|
|
General Specifications |
|
|
Dimensions (H x W x D) |
|
3.0 x 4.75 x 1.1" (75.5 x 120 x 27.3 mm) |
|
|
Weight (not including shunt) |
|
4.6 0z (130.4 g) |
|
|
Warranty |
|
1 year |
|
|
Part number |
|
84-2019-02 |